Factory Seconds Spec Sheets.indd
Current Voltage Curves at STC
Current Voltage Curves at STC
Relative Efficiency
EPV-4X, EPV-5X
Relative Efficiency
Module Current (A)
Module Current (A)
Module Voltage (V)
Irradiance (W / m2 )
Solar Module
Module Voltage (V)
Irradiance (W / m2 )
Advanced Thin-film Photovoltaic Technology
IV Curve
Dependence on Temperature
Electrical Specifications
EPV-4X Series
EPV-5X Series
40W
42W
50W
52W
54W
56W
58W
Rated Power (+/- 5%)
Pmax (W)
40
42
50
52
54
56
58
Voltage at Maximum Power
Vmp (V)
44
45
45.0
45.5
45.4
46.2
46.5
Current at Maximum Power
Imp (A)
0,92
0,94
1.12
1.15
1.19
1.22
1.25
Open Circuit Voltage
Voc (V)
59
60
60
60
60.6
61.7
62.3
Short Circuit Current
Isc (A)
1,17
1,18
1.41
1.44
1.49
1.51
1.54
Maximum System Voltage
Vsys (V)
1,000V (IEC) / 600V (UL)
IEC / UL
Temperature Coefficient of Pmax
Tk (Pmax)
-0,19 %/°C
Temperature Coefficient of Voc
Tk (Voc)
-0,28 %/°C
Temperature Coefficient of Isc
Tk (Isc)
+0,09 %/°C
222mm
724mm
108mm
711mm 381mm
362mm
Wire Boot
355mm
Mounting Bracket
26mm
7mm
1321mm
Diagram for EPV-5X Series Measurements
Mechanical Specifications
EPV-4X Series
EPV-5X Series
Length
1245 mm +/- 3 mm
1321 mm +/- 3 mm
Width
635 mm +/- 3 mm
711 mm +/- 3 mm
Thickness (including wiring boot)
7 mm (24 mm including wiring boot)
Weight
12,3 kg
14,5 kg
Module Area
0,79 m²
0,94 m²
Bypass Diode
None
Module Type
a-Si (amorphous silicon)
Frame Material
Frameless
Glass Type
0.125 in / 3 mm annealed glass on front and back
Encapsulation
EVA (ethylene vinyl acetate)
Output Cable / Connectors
14 AWG single insulated or 2.5mm double insulated with
quick connect connector
CAUTION: READ USER’S GUIDE BEFORE USING THIS PRODUCT
Electrical specifications are rated at Standard Test Conditions STC (Irradiance of 1000W/m², AM 1.5, cell temperature 25°C). During the stabilization process that occurs during the first few months
in service, module power output will exceed specified ratings. Power output may be higher by 20%; operating voltage may be up to 10% higher; operating current may be up to 14% higher; and
short circuit current may be up to 10% higher.
EPVSOLAR
Warranty
25 year limited power output (80%)
2 year limited workmanship or materials
Certifications
•
DIN EN 61646:1998-03, EN 61646:1997 e IEC 61646 (ed 1) certified
by VDE
•
Safety Class II according to DIN VDE 0110-1:2003-11, IEC 61730-1
and IEC 61730-2.
•
Conforms to UL 1703 and ULC/ORD-C1703-1
•
2400 N/m2 mechanical load-bearing capacity, for both the module and
the interface with the mounting system (backside brackets) per IEC
61646.
•
Repeated measurements of the electrical parameters and insulation
properties during the manufacturing process
•
Product tested by independent recognized laboratories..
Stabilization values
During the stabilizations process that occurs during the first months in
service, module power output will exceed specified ratings. Power output
may be higher by 20%, operating voltage may be up to 10% higher,
operating current may be up to 14% higher, and short circuit current may be
up to 10% higher.
Applications
•
Grid-tied systems
•
Off-grid systems
•
On rooftops
•
Free-standing
•
For BiPV applications please refer to specific products.
Advantages
•
High temperature and low light performance
•
Shadow tolerance
•
High efficiency under low radiation conditions.
•
Very low mismatch effects
•
New flexible mounting systems
EPVSOLAR USA
Inverter selection
8 Marlen Drive
Robbinsville, New Jersey 08691 USA
USA
The selection of the inverter should be done in accordance of avoiding
Ph: 1.609.587.3000 Fax: 1.609.587.5355
negative voltages on the solar generator against ground. Therefore, EPV
Solar recommends the use of inverter topologies/designs which allow and
secure having ground potential or similar at the negative pole of the solar
www.epvsolar.com
array.
sales@epvsolar.com
Shading and bypass diodes
Modifications to technical data are possible without prior notice.
Please request the current data sheets from EPV SOLAR before
According to the internal cell structure of EPV modules, no bypass or
using our products. EPV SOLAR assumes no responsibility
blocking diodes are required as long as the connection of a maximum of 8
for damage caused to equipment connected to EPV modules
strings in parallel is observed
that are not operated in accordance with the relevant technical
In case of possible shading, please install the modules observing that
information. The instructions in the Installation and User Guides
must always be observed (i.e. max 8 strings in parallel without
laser lines run perpendicularly to the shadow. In this way the relationship
external protection, use of compatible inverters).In case of any
between the shaded area and the output loss will be linear.
question please do not hesitate to contact our technical team.